Relation between Ex zones, categories,protection types and EPLs
-
Explosive gas atmospheres
-
Equipment with protection levels Ma and Mb are classified as EN IEC 60079-0 standard relevant Group I equipment, in categories M1 and M2, and are used in ATEX Group I gas atmospheres.The hazardous zone classification does not apply to equipment with protection level M.
-
Equipment with protection levels Gb, Ga, and Gc are classified as EN IEC 60079-0 standard relevant Group II equipment, in categories 2G, 1G, and 3G, and are used in atex Group II gas atmospheres.
-
Protection type |
Subset protection |
Equipment protection level (EPL) |
Group based onEN IEC 60079-0 |
Group based onATEX directive |
Category based onATEX directive |
Hazardous zone based onEN 60079-10-X |
---|---|---|---|---|---|---|
Exd |
da |
Ga |
II |
II |
1G |
0 |
Ma |
I |
I |
M1 |
not applicable |
||
db |
Gb |
II |
II |
2G |
1 |
|
Mb |
I |
I |
M2 |
not applicable |
||
dc |
Gc |
II |
II |
3G |
2 |
|
Exe |
eb |
Gb |
II |
II |
2G |
1 |
ec |
Mb |
I |
I |
M2 |
not applicable |
|
Exi |
ia |
Ga |
II |
II |
1G |
0 |
Ma |
I |
I |
M1 |
not applicable |
||
ib |
Gb |
II |
II |
2G |
1 |
|
Mb |
I |
I |
M2 |
not applicable |
||
ic |
Gc |
II |
II |
3G |
2 |
|
Exm |
ma |
Ga |
II |
II |
1G |
0 |
Ma |
I |
1 |
M1 |
not applicable |
||
mb |
Gb |
II |
II |
2G |
1 |
|
Mb |
I |
1 |
M2 |
not applicable |
||
mc |
Gc |
II |
II |
3G |
2 |
|
Exn |
nA |
Gc |
II |
II |
3G |
2 |
nC |
Gc |
II |
II |
3G |
2 |
|
nR | Gc | II | II | 3G | 2 | |
Exo | ob | Gb | II | II | 2G | 1 |
oc | Gc | II | II | 3G | 2 | |
op is | Ga | II | II | 1G | 0 | |
Gb | II | II | 2G | 1 | ||
Gc | II | II | 3G | 2 | ||
Ma | I | I | M1 | not applicable | ||
Mb | I | I | M2 | not applicable | ||
op pr | Gb | II | II | 2G | 1 | |
Gc | II | II | 3G | 2 | ||
Mb | I | 1 | M2 | not applicable | ||
op sh | Ga | II | II | 1G | 0 | |
Gb | II | II | 2G | 1 | ||
Gc | II | II | 3G | 2 | ||
Ma | I | I | M1 | not applicable | ||
Mb | I | I | M2 | not applicable | ||
Exp | pv | Gb | II | II | 2G | 1 |
Gc | II | II | 3G | 2 | ||
pxb | Gb | II | II | 2G | 1 | |
Mb | I | 1 | M2 | not applicable | ||
pyb | Gb | II | II | 2G | 1 | |
pzc | Gc | II | II | 3G | 2 | |
Exq | __ | Gb | II | II | 2G | 1 |
Mb | I | 1 | M2 | not applicable | ||
Exs | sa | Ga | II | II | 1G | 0 |
Ma | I | I | M1 | not applicable | ||
sb | Gb | II | II | 2G | 1 | |
Mb | I | I | M2 | not applicable | ||
sc | Gc | II | II | 3G | 2 |
End of table.
-
Explosive dust atmospheres
-
Equipment with protection levels Da, Db, and Dc are classified as EN IEC 60079 standard relevant Group III equipment, in categories 1D, 2D, and 3D, and are used in ATEX Group II dust atmospheres.
-
Protection type |
Subset protection |
Equpment protection level (EPL) |
Group based onEN IEC 60079-0 |
Group based onATEX directive |
Category based onATEX directive |
Hazardous zone based onEN 60079-10-X |
---|---|---|---|---|---|---|
Exi | ia | Da | III | II | 1D | 20 |
ib | Db | III | II | 2D | 21 | |
ic | Dc | III | II | 3D | 22 | |
Exm | ma | Da | III | II | 1D | 20 |
mb | Db | III | II | 2D | 21 | |
mc | Dc | III | II | 3D | 22 | |
Exop | op is | Da | III | II | 1D | 20 |
Db | III | II | 2D | 21 | ||
Dc | III | II | 3D | 22 | ||
op pr | Db | III | II | 2D | 21 | |
Dc | III | II | 3D | 22 | ||
op sh | Da | III | II | 1D | 20 | |
Db | III | II | 2D | 21 | ||
Dc | III | II | 3D | 22 | ||
Exp | pxb | Db | III | II | 2D | 21 |
pyb | Db | III | II | 2D | 21 | |
pzc | Dc | III | II | 3D | 22 | |
Exs | sa | Da | III | II | 1D | 20 |
sb | Db | III | II | 2D | 21 | |
sc | Dc | III | II | 3D | 22 | |
Ext | ta | Da | III | II | 1D | 20 |
tb | Db | III | II | 2D | 21 | |
tc | Dc | III | II | 3D | 22 |
End of table
Selecting the Hazard Zone for Explosion-Proof Equipment Operation
Equipment used for a specific area is selected based on the type or types of protection considered in their design. Not all protective techniques guarantee the same level of safety in a hazardous area, therefore specific protection methods are allocated to particular hazardous zones.
-
IEC 60079-10-1 is used for identifying, classification, and categorizing hazardous zones for gas atmospheres;
-
IEC 6079-10-2 is used for identifying, classification, and categorizing hazardous zones for dust atmospheres.